Blow Heaters

LPG-powered and designed for use in warehouses, workshops and worksites.

4 Results

Heaters FAQs

Can I use a Heat-Flo ™ Blow Heater with Natural Gas?

Heat-Flo ™ Blow Heaters can only be used with an LPG cylinder and can not be converted for use with Natural Gas.

Can you change or regulate the temperature on a Heat-Flo™ Blow Heater?

No. Each heater has a set gas input, so there is only 1 flame. If more or less heat is required, we have 4 different sizes available with different gas consumptions.

Which hose is supplied with a Heat-Flo ™ Blow Heater?

Each heater comes with a hose and regulator to connect to a 45kg cylinder. We do not provide any alternatives such as type 27, bayonet, or longer hoses.

Why do I have to connect my Heat-Flo™ Blow heater to a 45kg cylinder?

Our blow heaters have been tested and approved to the relevant AS/NZ standards using a 45kg cylinder. Due to compliance factors in place, we would request you follow the instructions mentioned in the manual.

How long will a Heat-Flo™ Tile Heater run on a 45kg LPG cylinder?

Heat-Flo™ Tile Heaters with more tiles generate more heat and therefore use more gas. Below are estimations on how long each heater runs for:

HeaterDuration
Heat-Flo 3 Tile Heat Deflector (2620162)90hrs
Heat-Flo 3 Tile Heater Surround (2620161)90hrs
Radiant Gas Heater Heat-Flo 3 Tile LPG (2620100-1)90hrs
Heat-Flo 5 Tile Heater Surround (2620172)50hrs

Can I use the Heat-Flo ™ Blow Heaters (HF15 / HF20 / HF30 / HF50) with NG?

No. It uses a POL or type 27 connection to an LPG cylinder, not a bayonet connection. This product is designed for LPG and should not be converted.  

Can you change the temp on the Heat-Flo ™ Blow Heaters?

No. Each heater has a set gas input and there is only 1 flame. Get a smaller or larger heater size for smaller or larger flame. 

How noisy are the Heat-Flo ™ Blow Heaters (HF15 / HF20 / HF30 / HF50)?

We do not have official noise data. They are designed for industrial settings, so noise was not a design factor, therefore they are relatively loud.

What clearances do the Heat-Flo ™ Blow Heaters (HF15 / HF20 / HF30 / HF50) need?

2.5m from heater outlet. 1.25m from the tops, sides and inlet. Never operate on elevated structures such as platforms or scaffolds.

Which blow heater should I choose?

To select the right heater, consider the volume of the room that you require heating. The larger the room, the higher KW output required to heat the room.

ModelMinimum room volume (m3)Heat Output (MJ/h)Airflow (m3/H)
HF1527054 MJ/h (15kW)500
HF2036072 MJ/h (72kW)500
HF30540108 MJ/h (108kW)1000
HF50900170 MJ/h (170kW)1000

Do you supply hoses with bayonet fittings?

As per the instruction manual, the inlet gas connection for the blow heater has size ¼” G LH thread. As per our specifications, these blow heaters are designed to be directly connected to the gas cylinder and so are provided with the corresponding hose connection. Unfortunately, we don’t have a hose which has the required thread to a bayonet connection. 

Gas Heaters - Frequently Asked Questions
Heaters - Category Description

About Bromic Blow Heaters

Bromic’s Heat-Flo™ blow heaters are LPG-powered and highly efficient, providing instant and economical heat. It features an automatic safety shut-off with loss of flame or power. A lightweight, durable and portable heating solution for industrial and outdoor applications.